If the cause cannot be determined, withdraw the device or system as a unit. Potential Adverse Events Possible complications include, but are not limited to, the following: allergic reaction and anaphylaxis from contrast media; acute occlusion; air embolism; arrhythmia; arteriovenous fistula; cardiac injury; cardio-respiratory arrest; death; device malfunction; distal embolization; emboli; excessive blood loss; false aneurysm formation; hematoma or hemorrhage at access site; inability to completely remove thrombus; infection; hemorrhage; ischemia; kidney damage from contrast media; neurological deficits including stroke; vessel spasm, thrombosis, dissection, or perforation; intimal disruption; myocardial infarction; emergent surgery; fibrillation; hypotension; hemoptysis; respiratory failure; thromboembolic events. Lightning comes packaged with the Indigo CAT7, CAT8 or CAT12. Do not use kinked or damaged devices. INDIGO Aspiration Tubing: In 2014, Penumbra broke into the peripheral thrombectomy space with the release of the first Indigo System catheters, the 5-F CAT5 catheter and the 3-F CAT3 catheter (Penumbra, Inc.). These pages are not intended for patients or for members of the general public. Since launch, we have found that CAT RX has become an essential part of our treatment algorithm when thrombus is present in the coronaries. Caution: Federal (USA) law restricts this device to sale by or on the order of a physician. TIMI 3 flow was achieved in 88% of cases. Angiography was performed and confirmed complete thrombus removal and flow restoration through the SVG. CHEETAH will focus on patients presenting with high-grade thrombus burden who receive frontline treatment with CAT RX. Lightning 7 expands Penumbra's offering of the Indigo Aspiration System with Intelligent Aspiration for mechanical thrombectomy and is designed for single session arterial thrombus removal. Common emitters (such as RFID emitters, security systems, diathermy equipment, and portable transmitters) should not be used in close proximity to the Penumbra ENGINE as they can interfere with and result in degradation of the performance of the equipment. Copyright 2023 Penumbra, Inc. All rights reserved. The CAT family of catheters is the foundation of Penumbras Indigo System. The Indigo Aspiration System should only be used by physicians who have received appropriate training in interventional techniques. . Disclosures: None. Available in a selection of sizes, the CAT family can provide access to distal peripheral vessels of the upper and lower extremities, including below the knee. Mechanical thrombectomy was performed. Warnings The Indigo Aspiration System is contraindicated in: Potential Adverse Events Reuse may result in canister cracking or vacuum filter blockages, which may result in the inability to aspirate. Use the INDIGO Aspiration System in conjunction with fluoroscopic visualization. . IN-DATE. right-arrow 1.10 Summary of Non-Clinical Data As required under Section 12, Part (a)(i)(3A) of the Safe Medical Devices Act of 1990, a Do not resterilize or reuse. The means of mains disconnect is to remove the power cord. Maintain a constant infusion of appropriate flush solution. 5 and 94. window.dataLayer = window.dataLayer || []; If such use is necessary, this equipment and the other equipment should be observed to verify that they are operating normally. The patient had reported intermittent chest discomfort for 3 days, with some improvement with his daily medications. A repeat mechanical thrombectomy was performed of the right superficial femoral artery with flow improvement. Penumbra CAT8XTORQ115 CAT8 Indigo System Aspiration Catheter 8F Item Past Expiration +1(833)330-3033. Figure 3. These were quickly followed by the release of the 8-F CAT8 and 6-F CAT6 in 2015. CAT RX mechanical aspiration system powered by Penumbra ENGINE in comparison to manual syringe-based aspiration. Possible complications include, but are not limited to, the following: acute vessel occlusion; air embolism; allergic reaction and anaphylaxis from contrast media or device material; anemia; arrhythmia; arteriovenous fistula; cardiac injury, cardiac perforation, cardiac tamponade; cardio-respiratory arrest; compartment syndrome; death; emboli; emergent surgery; foreign body embolization; hematoma or hemorrhage at access site; hemoptysis; hemorrhage; hypotension/hypertension; infarction leading to organ damage; infection; ischemia; myocardial infarction; neurological deficits including stroke; pneumothorax; pseudoaneurysm; renal impairment or acute renal failure from contrast media; residual thrombus due to inability to completely remove thrombus or control blood flow; respiratory failure; valvular damage; vessel spasm, thrombosis, dissection (intimal disruption), or perforation. This content is not intended to offer professional medical advice. Available in a selection of sizes, the CAT family can provide access to distal peripheral vessels of the upper and lower . UMassMemorial University Campus A CAT8 Penumbra catheter was advanced over the Glidewire into the right superficial femoral artery. Penumbras Indigo Aspiration System can be used to remove emboli and thrombi from vessels of the peripheral arterial and venous systems, and for the treatment of pulmonary embolism and/or certain central circulatory system conditions such as pulmonary emboli. The procedure was completed with the same catheter. Mechanical clot engagement with proprietary Separator technology, Tip directionality for circumferential aspiration, The Indigo System is an integrated system for use only with other components of the Indigo System including the CAT family of catheters, Separators, Dynamic Aspiration Tubing, Lightning, Penumbra ENGINE, and Penumbra ENGINE Canister, Lightning Computer-Aided Aspiration comes packaged with CAT7 or CAT12, Live feedback during the procedure with integrated clot catcher, Penumbra ENGINE is capable of delivering and maintaining nearly pure vacuum (-29 inHg or 98.2 kPa) with the disposable Penumbra ENGINE Canister. Prior to use, please refer to the Instructions for Use for complete product indications, contraindications, warnings, precautions, potential adverse events, and detailed instructions for use. The Indigo Aspiration System is intended for the removal of fresh, soft emboli and thrombi from vessels of the peripheral arterial and venous systems and certain central circulatory system conditions such as pulmonary emboli using continuous aspiration. To prevent fire or shock hazard, use a replacement power cord of equal rating. Placing guidewire too distal in the pulmonary vasculature or excessive manipulation of aspiration/ guiding catheter in the smaller, peripheral, and segmental pulmonary artery branches can result in vessel perforation. For more information on the personal data that is collected by this website, please refer to Penumbras Privacy Notice. The four cathetersCAT3, 5, 6, & 8are robust, durable, trackable, and suited for the peripheral anatomy. 22. The CAT family of catheters is the foundation of Penumbra's Indigo System. Saxon RR, Benenati JF, Teigen C, et al. She had a recent embolic cerebrovascular accident (CVA) with a hemorrhagic conversion and right-sided hemiparesis but was otherwise known to be very functional. Ruby Coil, POD, and Packing Coil are large-volume coils designed for embolization of the peripheral arterial and venous systems. Sista A. Indigo aspiration system for acute pulmonary embolism. This is potentially more effective than diminished syringe-based aspiration. A 65-cm 8-F Destination sheath (Terumo Interventional Systems) was advanced into the right pulmonary artery, first over a telescoping balloon tip catheter and stiff angle Glidewire (Terumo Interventional Systems). waqas.qureshi@umassmemorial.org This is potentially more effective than diminished syringe-based aspiration. Do not use INDIGO SEPARATOR 4 to macerate or retrieve thrombus distal to the catheter tip. Available in a selection of sizes, the CAT family can enable access to distal peripheral vessels of the upper and lower extremities, including below the knee. Indigo System | Computer-Aided Mechanical Aspiration. No modification of this equipment is allowed. INDIGO Aspiration Catheters and Separators: As part of the INDIGO Aspiration System, the INDIGO Aspiration Catheters and Separators are indicated for the removal of fresh, soft emboli and thrombi from vessels of the peripheral arterial and venous systems, and for the treatment of pulmonary embolism. Common emitters (such as RFID emitters, security systems, diathermy equipment, and portable transmitters) should not be used in close proximity to the PENUMBRA ENGINE as they can interfere with and result in degradation of the performance of the equipment. Suhail Dohad, MD, FACC The CAT familyof catheters is the foundation of Penumbras Indigo System. As part of the Indigo Aspiration System, the Indigo CAT RX Aspiration Catheters and Indigo Separator 4 are indicated for the removal of fresh, soft emboli and thrombi from vessels in the coronary and peripheral vasculature. Otherwise, this could result in degradation of the performance of this equipment. The system uses Penumbra's RED reperfusion catheters. Peripheral Thrombectomy Indigo System Mechanical Thrombectomy CAT6 Indigo Catheter 6, Straight tip 135cm. This website is intended for US audience only. LIGHTNING Aspiration Tubing Indication for Use Initial experience with a mechanical aspiration catheter for thrombus removal during percutaneous intervention: a multicenter retrospective case series. Indigo Aspiration Catheters (CAT) are the foundation of Penumbras IndigoSystem. Presented at: Vascular InterVentional Advances (VIVA); November 47, 2019; Las Vegas, Nevada. This content is not intended to offer professional medical advice. Indigo Aspiration Catheters (CAT) are the foundation of Penumbra's Indigo System.The Indigo System CAT3, CAT5, CAT6, CAT8 and CATD are engineered to be robust, durable, and trackable for use in the peripheral anatomy. 3D, 3D Revascularization Device, ACE, Artemis, BENCHMARK, CAT, Indigo, LANTERN, Lightning, MAX, Neuron, Neuron MAX, Penumbra Coil 400, Penumbra ENGINE, Penumbra P logos, Penumbra System, Penumbra SMART COIL, POD, PX SLIM, Ruby, Select, Separator, Velocity, and WAVE are all registered trademarks or trademarks of Penumbra, Inc. in the USA and other countries. Jolly SS, Cairns JA, Yusuf S, et al. Penumbra ENGINE Intended Use 5, 19. The advantages of CAT RX with Penumbra ENGINE include the potential to remove the thrombus intact and reduce the potential of systemic embolization while also increasing the visualization of the underlying stenosis and distal vessel. There was partial improvement of flow, but total occlusion remained. Precautions The safety and effectiveness of this device for use in the treatment of ST-Elevation Myocardial Infarction (STEMI) has not been established. Get Penumbra Cat 8 in Secunderabad, Hyderabad, Telangana at best price by Zephyr Technologies. This warranted the need for further innovation in the field of acute coronary syndrome.2 The goal of the Indigo System CAT RX mechanical aspiration system powered by the Penumbra ENGINE is to provide sustained aspiration for the duration of the procedure with enhanced deliverability to navigate tortuous anatomy and track to the distal coronary vasculature. Most recently, Penumbra launched LP System, including Ruby Coil LP and Packing Coil LP, which are low profile microcatheter compatible (.0165 - .021 ID). Gus Theodos, MD, FACC, FSCAI Return all damaged devices and packaging to the manufacturer/distributor. If repositioning of the INDIGO Aspiration Catheter is necessary during the revascularization procedure, such repositioning should be performed over an appropriate guidewire using standard catheter and guidewire techniques. Penumbra CAT8XTORQ115 CAT8 Indigo System Aspiration Catheter 8F Item Past Expiration. SVG occlusions can be challenging to resolve using traditional treatment modalities. The procedure can be performed quickly,1 which is important for symptomatic patients. If such use is necessary, LIGHTNING Aspiration Tubing and the other equipment should be observed to verify that they are functioning properly. Aspiration or disruption of thrombus with traditional diminished syringe-based aspiration or other mechanical devices is difficult, often incomplete, and has been associated with high complication rates.1 Use of medical therapy, such as powerful anticoagulants and thrombolytics (ie, tissue plasminogen activator), may carry a high risk of bleeding.2 The Indigo System was designed to provide sustained aspiration with Penumbra ENGINE to effectively remove thrombus, while reducing the risk of bleeding complications.3 The Indigo System utilizes atraumatic catheters varying in diameters from 3.4 to 8 F and lengths ranging from 50 to 150 cm. Initial angiogram of the right pulmonary artery showing pulmonary embolism. Caution: Prior to use, please refer to the Instructions for Use for complete product indications, contraindications, warnings, precautions, potential adverse events, and detailed instructions for use. Tip directionality for circumferential aspiration, Live feedback during procedure with integrated clot catcher, Penumbra ENGINE is capable of delivering and maintaining nearly pure vacuum (-29 inHg or 98.2 kPa) with the disposablePenumbra ENGINE Canister. The initial angiogram confirmed an occlusion with extensive thrombus burden of a dominant left circumflex artery and TIMI 0 flow (Figure 1). Caution: Prior to use, please refer to the Instructions for Use for complete product indications, contraindications, warnings, precautions, potential adverse events, and detailed instructions for use. Indication For Use The Indigo System utilizes the Penumbra ENGINEaspiration source capable of delivering nearly pure, continuous vacuum to our catheters to remove thrombus in vessels of various sizes. Otherwise, this could result in degradation of the performance of this equipment. Use prior to the Use By date. Most recently, Penumbra launched Lightning Intelligent Aspiration which enables physicians to focus on optimizing thrombus removal using the system's unique clot detection mechanism. Do not block bottom air vents. The Penumbra Aspiration Pump is indicated as a vacuum source for Penumbra Aspiration Systems. minimalism: a documentary about the important things transcript; cat8 penumbra catheter; i 75 road construction cincinnati; tocaya west hollywood; best places to live in alabama near the. Potential Adverse Events Use prior to the Use By date. Figure 1. Warnings/Precautions The canister is intended for single use only. The patient vomited the ticagrelor within 2 hours of administration and cangrelor was started. After one pass with CAT RX, the initial occlusion was removed. Angiograms showed pre- and postthrombectomy of the right pulmonary artery with modest clot debulking but significant improvement in right lung perfusion. 1. Jawairia Sahar K. Mirza, MBBS PENUMBRA ENGINE Intended Use window.dataLayer = window.dataLayer || []; INDIGO Aspiration Tubing: As part of the INDIGO Aspiration System, the INDIGO Sterile Aspiration Tubing is indicated to connect the INDIGO Aspiration Catheters to the Penumbra Aspiration Pump.
True Life I'm Addicted To Tanning Alyssa Last Name,
Articles C